October 23-25, 2018
Defense TechConnect Fall Summit & Expo
Tampa, Florida



P/N: ETI0001-1473 2.0 kVA Rugged Rackmount COTS WAAS UPS with Internal Intelligent PDU

Part Number: ETI0001-1473 
Rugged COTS 2000 VA Combination
Integrated
Rackmount UPSand Intelligent Power Distribution Unit


Rugged COTS
Product
Ultra Quiet 2000 VA Rack Mount, w/ Integrated 8 Circuit, Intelligent, Solidstate Power Distribution Unit
UPS

ETI0001-1473 Rugged COTS UPS and PDU Standard Front Panel Layout
P/N: ETI0001-1473 Rugged COTS
and  Standard Front Panel Layout

ETI0001-1473 Rugged COTS UPS and PDU Standard Rear Panel Layout
P/N: ETI0001-1473 Rugged COTS
and  Standard Rear Panel Layout

The field proven Rugged Systems™ UPS line is ideally suited for , industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The ETI0001-1473 was specifically designed to meet the stringent requirements of . The ETI0001-1473 does not require a separate PDU since the PDU functions are already integrated into the UPS module. This saves rack space, cabling and expense while improving overall reliability.

delivers up to 2000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, both front and rear, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration in any axis. 

domestic VAC The optional autoranging 85-270 VACCONUS OCONUS)internal input transformer. he input circuit breaker and the galvanic isolation transformer provide a double pole isolated source for overseas locations where phase references and grounding are not consistent. 

Special EMI/RFI filters and input power factor correction minimize both input current and harmonics.

The Elapsed Time Indicator records the number of operational hours for records and scheduling preventative maintenance of attached equipment. The front and rear panels also provide easy access to both the AC Input and Battery Input fuses. Coupled with the adjacent spare fuses, MTTR is reduced to less than 15 minutes.

The internal intelligent thermal sensors provide two stage monitoring of unit temperatures,with both local and remote capability of thermal shutdown. can be engaged via the front panel control, via a remote contact input or via a software command. When in , an audible alarm is sounded and an indicator is lit. The high intensity audible alarm can be heard in high noise environments and includes an audible enable/disable switch. 

All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety. push/pull circuit breakers provide both circuit protection and manual controls. Both the input and load circuit breakers are shock rated to over 100 Gs. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console, or on the unit front panel with only a logic level cable connection. 

The rear panel provides locking connectors for the input and output power with various optional configurations available. This unit draws air through the front air filter and exhausts out the rear vent into the rack. This allows the unit to be used in either negative or neutral pressure racks. The fan is a special extra quiet version to keep the unit's overall audible level below 44 dB. 

The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability PDU Remote Control connector provide an interface to optional remote display/control panels. The RJ45 LAN port provides an SNMP/HTTP interface for various UPS parameters.

The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. See the Power Distribution Units section for a listing of stand alone PDUs. See the N3 Series for a version of UPS without the integrated PDU and remote control.

Overall, the PowerStation line is uniquely qualified for critical systems combining advanced modular design features with highly reliable construction.

Technical Specifications: ETI0001-1473

AC OUTPUT
Output voltage: 120 VAC true sinewave standard
Output rating: 2000 VA, 1500 watt max standard in 3U chassis
Non-linear load capacity: Up to 100% non-linear load capability w/o derating
Output voltage regulation: ± 3.0% static regulation of nominal
± 4.0% dynamic (0 to 50% load step)
Overload surge capacity: 110% for 10 minutes; 125% for 30 seconds
Harmonic distortion: Less than 5.0% into 100% non-linear load
Output frequency: 60 or 50 Hz ± 2.5% synchronized to utility
60 or 50 Hz ± 1.0% w/ utility not available
400 or 1000 Hz output available as an option
Operational status AC Input status, UPS operational, UPS alarm, Battery level, Low battery, Load level, Overload, Warm temperature, Hot temperature and Battleshort LEDs, Elapsed time hour meter
Alarm contacts for Loss of AC and Low Battery
dB audible alarm with audible on/off switchAsynchronous serial COM port, 10BaseT Ethernet SNMP/HTTP port, 
DC OUTPUT
Output voltage / rating: DC 2 VDC / 300 watt
Output voltage regulation: ± 2.0% static regulation of nominal
Overload surge capacity: 110% continuously
Output protection: Front panel mounted
AC INPUT
Input voltage selection: Nominal 1 VAC
Input voltage tolerance: UPS 85-135 VAC @ full load without using battery, 
Down to 70 VAC @ 75% load
Input frequency: From 46 Hz to 70 Hz standard, optional to 440 Hz
Input power factor: Better than 99% typically
Input/output isolation: 2000 VA, up to 120 dB common mode, 
<1.0 mA leakage
Input transient suppression: Complies with IEEE 587, UL 1449 and Mil Std 1399
Input control/protection: Guarded 2 pole 100 G shock rated circuit breaker (CB1) plus UPS input fuse (F2), spare fuse on front
Optional cold start to turn on w/o AC present
Input power connection: locking
DISTRIBUTION
Output circuits: Eight controlled outputs via solidstate relays
Output control: Local control panel with (8)  
Shock Rated Push/Pull Circuit Breakers
Thermal and remote interlock ON/OFF control
Output receptacles:  
DISTRIBUTION
Output circuits: controlled outputs via solidstate relays
Output control: Local control panel with ()  
Shock Rated Push/Pull Circuit Breakers
Output receptacles:  
EXTERNAL BATTERY
Battery type: Maintenance free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+)
Battery life: Rated for continuous service life of 5 years
DC protection: Panel mounted fuse standard, breaker optional
Battery expansion: Up to 24 hours w/ Battery Expansion Modules
MECHANICAL
Dimensions (H x D x W):
Battery Module

5.25 (3U) x x 19.0 in (133 x x 483 mm)
3.50 (2U) x 1.5 x 19.0 in (89 x x 483 mm)
Rack Slide Mount Patterns: Jonathan, General Devices patterns standard, 
Others optional
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Unit weight:

Battery Module
lb. ( kg) UPS with lift handles front and rear
55 lb. (25 kg) Battery with lift handles front and rear
Audible noise: Less than 44 dB @ 5.0 ft., ANSI "A" scale
Cooling type: High capacity, negative pressure, forced air
Cooling air direction: Front intake, exhaust to rear, others optional
Air intake filter: Washable metal filter media, others optional
ENVIRONMENTAL
Storage temperature: -40° to 158° F ambient (-40° to 70° C) with fully charged batteries
Operating temperature: 32° to 126° F ambient ( 0° to 52° C), lower / higher optional
Operating humidity: 0 to 95% relative humidity (non-condensing)
Storage elevation: Up to 40,000 ft (12,192 m)
Operating elevation: Up to 15,000 ft (4,572 m), higher optional
STANDARDS
United States: Meets UL-1778 standard for UPS equipment,
MIL STDs 167-1, 454, 810, 901D Grade A, 
1399-300A & 2000
Canada: CSA C22.2 No. 107 UPS safety requirements
EMI Protection: EMI/RFI FCC Part 15, Class A; 
EN55022; MIL STD 461 
OPTIONAL ACCESSORIES
  Autoranging International Input, Cold Start, Alternate I/O Configurations, Battery , Battery Charger/Conditioner, Power Distribution Units, Software Interface, Transport Cases, Slides and Mounting Kits

: November 23, 2011

Product Inquiry
*(denotes required field)
Contact ETI by mail at:
Energy Technologies, Inc.
219 Park Avenue East
Mansfield, OH 44902-1845
USA

Contact ETI by phone or fax:
Voice: 419-522-4444
FAX: 419-522-4466