February 13-15, 2019
AFCEA / WEST 2019
San Diego, California



P/N: ETI0001-1451 4.0 kVA Rugged Rackmount MilSpec UPS with Internal Intelligent PDU

Part Number: ETI0001-1451
Rugged Mil Spec 4000 VA Integrated
Rackmount UPS and Intelligent
Power Distribution Unit Combination

US Navy Standard for Q70 and TAMPS,
PowerStation
Isolated Mil Spec 4000 VA UPS,
Rugged Rack Mount UPS  w/ PFC and Integrated 6 Circuit, 
Intelligent, Solidstate Power Distribution Unit

P/N: ETI0001-1451 Rugged MilSpec UPS and PDU Standard Front Panel Layout
ETI0002-0594 Rugged UPS Battery Module Front View
P/N: ETI0001-1451 Rugged Mil Spec UPS and PDU Standard Front 
Panel Layout w/ 3U Battery Module

P/N: ETI0001-1451 Rugged MilSpec UPS and PDU Standard Rear Panel Layout
P/N: ETI0001-1451 Rugged Mil Spec UPS and PDU Standard Rear 
Panel Layout w/ 3U Battery Module

The field proven Rugged Systems™ UPS line is ideally suited for military, industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The "ETI0001-1451" was specifically designed for US Navy rack systems requiring higher power requirements. In typical installations, the 3U electronics module is mounted in the upper section of the rack near eye level. The "ETI0001-1451" does not require a separate PDU since the PDU functions are already integrated into the UPS module. This saves rack space, cabling and expense while improving overall reliability. The heavier 3U battery module is then mounted in the bottom of the rack for lowering the center of gravity of the rack. A 12 foot heavy duty shielded cable is provided to connect the two modules.

Both chassis have rounded metal corners and rugged handles, both front and rear, aiding in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration in any axis. These units can be mounted horizontally or vertically.

The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optional autoranging international input voltages (85-270 VAC, OCONUS). Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The input circuit breaker and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent. 

The LED arrays keep the operator informed as to the unit's status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety, plus Battleshort override. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console, or on the unit front panel with only a logic level cable connection.

The rear panel provides locking connectors for the input and output power with various optional configurations available. The output connectors are standard NEMA 5-15R with unique cable restraints. This reverse air flow version draws air through the front and exhausts out the rear vents into the rack. A removable and washable intake air filter and high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments.  The external battery connector allows the safe and easy addition of the standard or extra battery modules without having to shut the unit down. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. A frequency selection switch is available for those sites requiring 50 hertz output instead of the standard 60 hertz. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability. The PDU Remote Control connector provides an interface to optional remote display/control panels. 

See the Power Distribution Units section for a listing of stand alone PDUs. See the N3 Series UPS section for UPS without the integrated PDU and remote control.

Overall, the PowerStation line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction

Technical Specifications: ETI0001-1451

AC OUTPUT
Output voltage: 120 VAC true sinewave standard, others optional
Output rating: UPS 4000 VA standard in 3U electronics chassis
0.65 to 0.75 pf standard, optional configurations to 24,000 VA
Non-linear load capacity: Up to 100% non-linear load capability w/o derating
Output voltage regulation: UPS ± 3.0% static regulation of nominal
± 4.0% dynamic (0 to 50% load step)
Overload surge capacity: 110% for 10 minutes; 125% for 30 seconds
Harmonic distortion: Less than 5.0% into 100% non-linear load
Output frequency: UPS 60 or 50 Hz ± 2.5% synchronized to utility
60 or 50 Hz ± 1.0% w/ utility not available
400 or 1000 Hz output available as an option
Operational status Status, load and battery level LEDs, w/contacts
Adjustable level,+90 dB audible alarm w/on/off
AC INPUT
Input voltage selection: Nominal 115 VAC, optional autoranging input of 85-270 VAC
Input voltage tolerance: UPS 85-135 VAC @ full load without using battery, to 70 VAC @ 75% load
Input frequency: From 46 Hz to 70 Hz standard, optional to 440 Hz
Input power factor: Better than 99% typically
Input/output isolation: 4000 VA, up to 120 dB common mode, <1.0 mA leakage
Input transient suppression: Complies with IEEE 587 and UL 1449
Input control/protection: Guarded 2 pole input breaker w/ UPS fuses
Optional cold start to turn on w/o AC present
Input power connection: AMP MCPC 7-pin Type XII threaded locking
EXTERNAL BATTERY
Battery type: Maintenance free immobilized electrolyte,
Flame retardant materials, Oxygen Index 28+
Battery life: Rated for continuous service life of 5 years
DC protection: Panel mounted fuses standard, breaker optional
Battery expansion: Up to 24 hours w/ Battery Expansion Modules
DISTRIBUTION PANEL
Output circuits: Six controlled outputs via solidstate relays
Output control: Local/remote control panel w/rocker switches
Thermal and remote interlock ON/OFF control
Output receptacles: NEMA 5-15R w/ cable lock, various options
MECHANICAL
Dimensions ( H x D x W ):
  UPS Module
  3U Battery Module

5.25 (3U) x 23.5 x 19.0 in (133 x 597 x 483 mm)
5.25 (3U) x 23.5 x 19.0 in (133 x 597 x 483 mm)
Rack Slide Mount Patterns: Jonathan, General Devices patterns standard, others optional
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Shipping weight: 
  UPS Module
  3U Battery Module

  95 lb. (  43 kg) with lift handles front and rear
158 lb. (  72 kg) with lift handles front and rear
Audible noise: Less than 47 dB @ 5.0 ft., ANSI "A" scale
Cooling type: High capacity, negative pressure, forced air
Cooling air direction: Front intake, exhaust to rear, others optional
Air intake filter: Washable metal filter media, others optional
ENVIRONMENTAL
Storage temperature: -40° to 158° F ambient (-40° to 70° C) with fully charged batteries
Operating temperature: 32° to 113° F ambient (0° to 45° C ), lower/ higher optional
Operating humidity: 0 to 95% relative humidity (non-condensing)
Storage elevation: Up to 40,000 ft (12,192 m)
Operating elevation: Up to 15,000 ft (4,572 m), higher optional
STANDARDS
United States: Meets UL-1778 standard for UPS equipment,
MIL STDs 167-1, 454, 810, 901D Grade A, 1399-300A & 2000
Canada: CSA C22.2 No. 107 UPS safety requirements
EMI Protection: EMI/RFI FCC Part 15, Class A; EN55022; MIL STD 461 
OPTIONAL ACCESSORIES
  Autoranging International Input, Cold Start, Alternate I/O Configurations, Dual Source Input, Battery Expansion, Batteryless Operation, Battery Charger/Conditioner, Power Distribution Units, Software Interface, Asynchronous serial COM port, 10BaseT Ethernet SNMP/HTTP port,  Transport Cases, Slides and Mounting Kits